ZHURIN ELECTRONICS Co., Ltd.

Optoelectronic passive infrared single-position detectors "SPLAV L50M" with a linear zone length of 50 meters (30 meters in outdoor conditions) and a height/width of the zone at a maximum distance of 2x3 meters. Designed to work as part of the complex "Murena Eel-K" and protect extended areas (perimeters) both outdoors and indoors by issuing an alarm notification when an intruder crosses a linear detection zone of up to 50 meters at speeds from 0.1 to 5 m/s.

Optoelectronic passive infrared single-position detectors SPLAV L50M

Main technical characteristics:

  • External power supply voltage: 4-30V
  • Current consumption: 2.5/7.5 mA
  • Dual relay with normally-closed and normally-open contacts
  • Direct switching of low-power sound or light sounders
  • Integrated bracket
  • Outdoor version (enclosure protection class IP65)
  • Operating temperature range: -40..+60aboutWith
  • Dimensions: 145x105x80 mm

Detection zone

Top view

Side view

Detector detection zone SPLAV L50

Description:

The SPLAV L50 linear detectors use fully digital detection technology. The infringer detection algorithm is registered as intellectual property (certificate No. 2006612146 dated 06/20/06 ROSPATENT).

To increase the stability of the linear detector in difficult conditions, it is possible to set an adaptive mode or one of 15 fixed sensitivity levels. The estimated range of stable operation in outdoor conditions is 30 meters.

The presence of a dual relay with normally-closed and normally-open contacts allows direct switching of low-current sound or light sounders. The integrated bracket is designed for mounting the detector on a wall or pole.

 

Advantages:

  • requires no battery replacement or disassembly maintenance
  • Compatible with most security systems from other manufacturers that use a wired alarm system
  • can be used with low-power sound or light sounders without additional equipment
  • Easy to set up and easy to operate

Features:

  • they are used as part of the Murena-K complex
  • Installation of a wired alarm and power transmission system is required
  • reception equipment or alarm system is required

  • linear infrared up to 50m
  • external power is required
  • receiving equipment or an alarm system is required
  • no battery replacement required
  • for use in the Murena-K complex

ZHURIN ELECTRONICS Co., Ltd.

ZHURIN ELECTRONICS Co., Ltd.

Телефон: +79023533074

email: info@zhurin.com